The OmniPro II is HAI's flagship automation and security controller. It is designed for large residences and commercial installations. The system provides enhanced comfort, safety, convenience and energy savings by coordinating lighting, heating and air, security, scenes and messaging based on activity and schedules.

OmniPro II features the most powerful version of HAI's Advanced Control Programming (ACP) logic that allows installers and owners to set schedules and actions performed by the system.

 

Whole-House Scenes at the Touch of a Button:


OmniPro II comes with several standard modes, such as Day, Night, Away and Vacation, and can accept customized scenes such as "Good night", "Good morning" or "Entertainment" that set temperatures, lights and security to the desired levels with one touch. Security and temperature sensors can be used to adjust lights, appliances and thermostats, monitor activity and track events. The premises can be controlled and programmed on-site or from a remote location. Easy to read LCD consoles show status and allow control and scheduling of lighting, security, temperatures and accessories.

 

Access Your Home Systems Over the Web:


OmniPro II is HAI's most connectable system. In addition to connections for security devices, thermostats, light switches, telephone and backup battery, the OmniPro II features three built-in serial ports for connection to additional control devices, like HAI's Web-Link II and PC Access, and Connectivity Partner touchscreens, infra-red controls for entertainment, lighting controllers and computers. With optional Web-Link II, the OmniPro IIs control and monitoring features are available to any device on the home or business data network with a standard web browser, such as computers, PDAs, web-enabled TVs and web-tablets.

 

Rigorously Tested for Reliability:

 

Now in its sixth generation, the OmniPro II has passed the most rigorous product testing for reliability and resistance to surges and interference of any HAI product manufactured to date. It supports numerous Omni family accessories, including a complete line of fully communicating thermostats.

  

Omni Pro II Automation Features:

  • Controls up to 392 lights, appliances or groups: 256 via X10 power line carrier modules or 250 via UPB powerline carrier and/or 248 ALC switches using one or two optional 4-branch ALC Interfaces. It can also interface with Lutron Radio RA lighting controls.

  • 8 expandable to 136 voltage outputs

  • Temperature control for up to 64 Omnistat thermostats

  • OmniPro II sends time, outdoor temperature to thermostats for display

  • Time, Sunrise, Sunset, outdoor temperature display

  • Status display (on, off, level, mode, heat, cool, fan, temperature, etc.)

  • Temperature control for other items or existing thermostats using up to 176 temperature sensors or 136 PESMs

  • Enhanced Two-Way X-10 allows OmniPro II to receive signals for status tracking, use as program triggers, features collision detection and retry for reliability

  • Lights can be set to scenes of varying brightness, with Level, Ramp and Scene Support for architectural quality lighting control

  • Lights, control outputs, temperatures and security modes can be scheduled by time, sunrise, sunset, and date or day of week, as well as various system events

  • 1500 lines of non-volatile ACP control program storage

  • Commands (immediate and scheduled) include: on, off, dim, brighten, level, scene (and ramp rate for ALC) timed on, off, dim, bright, change settings, mode, fan for one or all thermostats, change system modes, zone status, flags, counters, timers, say, display or place a call with a message, activate a button (macro)

  • Supports HAI Pro-Link, which allows two-way serial communications with other controllers using ASCII messages

  • Event button capability ("Scenes" or "Macros") allows a series of commands to be executed at once, to create lighting scenes, occupancy modes, adjust temperatures, etc. initiated by: a console, computer, web-browser, or telephone command, a zone open or closed, a mode change (i.e. day, away, vacation),a particular user code entered,a time schedule, sunrise, sunset,incoming power line carrier, RS-232 or contact closure signals, other internal and external events

  • Enhanced ACP includes new commands for "real time pricing" of energy costs, and allows two conditionals per line for easier programming

  • Automatic Daylight Savings, global sunrise/sunset calculator

  • Expansion port for future SCP, UPnP, LonWorks or other interface

  • Ethernet Port 

Omni Pro II Security Features:

  • 16 zones, expandable to 176 zones

  • Supports two HA10A06 16 zone hardwire expanders, up to eight HA17A00 16 zone expansion enclosures, full selection of security zone types, key switch, outdoor temperature sensor, energy saver module, temperature control and/or alarm, auxiliary input for automation use (without security)

  • All zones support 4 wire smoke detectors

  • Zones 1 - 4 support 2 wire smoke detectors

  • 8 Hardwire Outputs, expandable to 136, fully configurable for: control output for automation, temperature control, long range radio armed, OK to arm, and others

  • LCD Consoles: Color LCD, Surface, & flush models available. Feature 4 wire connection, independent operation, 16 maximum, configurable beeper, viewing angle, backlighting

  • True Partitions: security and automation can be partitioned into 8 areas

  • Seven security modes: off, day, day-instant, night, night-delayed, away, vacation

  • 99 user codes with selectable authority levels

  • User codes can be made valid during certain times and days only, for maid, service, etc.

  • All lights on when alarm is tripped to help exit in case of fire, or frighten intruder away

  • Outdoor lights flashing when alarm is tripped to alert neighbors

  • Entry, exit and outdoor siren delays user programmable

  • Entry delay can be doubled or quadrupled on a zone to accommodate garage and back doors

  • Pre-alarm beeper and separate indoor siren outputs give owner time to turn off alarm before outdoor siren is activated

  • System announces type and location of alarm with optional two- way voice module

  • Auto-bypass feature means alarm won't go off unexpectedly if door or window is left open when the system is armed

  • Trouble conditions indicated on display

  • Phone line monitor

  • High Security Mode for commercial applications

  • All fire and burglary zones are fully supervised

  • Event Log with time and date

 

Omni Pro II Telephone Control Features:

  • Works with touchstone phones inside or away from the premises with access codes

  • Compatible with answering machines and answering services

  • Lockout feature discourages tampering with system by phone

  • Listen-in / talk to premises with optional two way voice module

  • From any phone you can change modes, change temperatures, arm/disarm security, bypass and restore zones and much more

Omni Pro II Digital Features:

  • Contact ID, 4/2 and 3/1 formats, dual round compared
  • Two phone numbers with two account numbers
  • Opening/Closing reports by user code

Omni Pro II Voice Dialer Features:

  • Dials up to 8 user programmable numbers and reports type and location of alarm

  • Called party can cancel dial out by entering code

  • Voice dialer is delayed by 5 minutes if digital dialer is used to allow central station to call back

  • Can call pagers, and be programmed to make a voice call based on a non-alarm event (example: call when children arrive home; call if "no activity" for elderly care)

Omni Pro II Reliability Features:

  • Designed for continuous trouble-free operation
  • Verifies smoke detectors by cycling power and confirming smoke alarm
  • System reads resistance of each zone independently to detect trouble due to faulty sensor or wiring before it causes false alarms
  • Fuse-less design, short circuit proof power supply and outputs, reset button for shorted outputs, short circuit indicator light

  • Programmable delay to preclude false alarms from user error
  • All inputs and outputs protected against static, RFI, surges, and lightning by use of impedance limits, spark gaps, TRANZORB surge arrestors, RC filters, MOVs, bypass capacitors and grounded shields
  • Watchdog timer, non volatile EEPROM storage for ALL programs, self diagnostic software, low voltage cut out, self protecting power supply for system integrity

Omni Pro II Easy of Use Features:

  • Text and voice descriptions for all zones, units, codes, macros, temperatures, messages, areas

  • Console display shows menus to guide users during use

  • Minimum keystrokes for common functions

  • Quick mode change feature

  • Optional wireless key fob for arming and control available

  • 500+ word speech vocabulary plus user recordable phrases